Fire Seperation for Granny Flats.

by | Feb 20, 2024

In Australia, complying with fire safety regulations, particularly concerning granny flats or secondary dwellings, is paramount for ensuring the safety of occupants and minimizing the risk of fire spread in residential areas. At KE Certifiers, we understand the importance of adhering to the specific provisions outlined in Volume Two of the National Construction Code (NCC) 2022.

Here are some key considerations regarding fire separation in granny flats:

  1. Boundary Walls: Boundary walls between the primary residence and the granny flat must meet specified fire-resistance levels to prevent the spread of fire. For instance, the NCC might require boundary walls to have a minimum fire-resistance level of 60/60/60, indicating their ability to withstand fire for 60 minutes from both sides.
  2. Party Walls: Party walls, shared between the main dwelling and the granny flat, should also meet certain fire-resistance requirements to contain fires within individual units and prevent horizontal fire spread. These walls may require a higher fire-resistance level than boundary walls.
  3. Minimum Separation Distances: The NCC may stipulate minimum distances between the main dwelling and the granny flat to mitigate the risk of fire spread. For example, there might be requirements for a minimum separation distance of 1.8 meters between these structures.
  4. Fire-Rated Construction: Fire-rated construction materials and assemblies, including walls, floors, and ceilings, must comply with specified standards to maintain fire separation between different parts of the building. These materials and assemblies must meet specified fire-resistance ratings to ensure adequate protection against fire spread.
  5. Openings and Penetrations: Regulations govern the protection of openings in fire-rated assemblies, such as doors and windows, as well as the use of fire stopping materials for penetrations through walls, floors, and ceilings. Fire-rated doors and windows installed in granny flats may need to have a minimum fire-resistance rating of 30 minutes.
  6. Occupancy Separation: Requirements exist for separating the main dwelling from the granny flat within the same building to minimize fire hazards and protect occupants. This may involve maintaining fire-rated barriers between residential units and secondary dwellings.
  7. Access and Egress: Guidelines ensure the provision of adequate access and egress routes for occupants of both the main dwelling and the granny flat to evacuate safely during a fire. This includes fire-resistant exit doors, stairwells, corridors, and clear pathways for emergency evacuation.

Compliance with these specific requirements outlined in Volume Two of the NCC 2022 is crucial for architects, builders, and developers to ensure the safe design and construction of granny flats or secondary dwellings. At KE Certifiers, we are committed to assisting our clients in navigating these regulations and achieving compliance to enhance fire safety and protect the lives and property of occupants in these structures.

Please contact us to discuss your specific project requirements.